OS32C Safety Laser Scanner

OS32C Safety Laser Scanner

OS32C Safety Laser Scanner Featuring the World's Most Compact Size (104.5 mm), Low Power Consumption (5 W) and Lightweight (1.3 kg).

  • Detection angle up to 270° provides coverage of two sides with one scanner.
  • 3m Safety zone, 10m Warning zone.
  • Easily-replaced sensor with no reprogramming, all configuration data is stored in the I/O block.
  • Integrated Management via Ethernet.
  • Flexible Zone Configurations with up to 70 sets of safety zone and warning zone combinations.
  • OS32C Safety Scanner Brochue

     

    e-Enquiry of OS32C

     

    Detection Angle Up to 270°

    A safety zone up to 3 m and warning zones up to 10 m can be set.

    Safety zone: 3 m max.; warning zones 1&2: 10 m max., detection angle: 270° max.  270° detection angle

     

    Integrated Management via Ethernet   Industry First 

    Industry's first Ethernet-compliant Safety Laser Scanner allows the user to check operating state and analyze the cause of an emergency stop via LAN even in large-scale applications using multiple scanners.

     

    Integrated management of safety laser scanner via Ethernet

     

    Replaceable Sensor, No Reprogramming Needed   NEW! 

    No reprogramming needed, the configuration is stored in the I/O block. Replacing a damaged sensor is fast and easy.

     

    Easily detached I/O block

     

    Flexible Zone Configurations   Industry Best 

    For complex AGV applications, up to 70 combinations - each with one safety zone and two warning zones - can be set. The two warning zones can be set to support various purposes such as warning sound and speed control.

     

    One safety zone and two warning zones

     

    Convenient and Easy-to-use Functions

     

    Operating State Can Be Determined at a Glance

    Eight sector indicators show the direction of intrusion. Front display shows operating state and error codes.

     

    Individual sector indicators: RUN, STOP, Interlock and Warning

     

    Reference boundary monitoring function   NEW! 

    The OS32C constantly monitors reference points and turns OFF the safety outputs when a shift in its position is detected.

    (Per international standard IEC 61496-3, area scanners used in applications where the angle of approach exceeds +/- 30 degrees with respect to the detection plane, must use RBM in the detection zone.)

     

    Gap occurs during turning off of safety outputs

    Provides Safety Category 3 safety circuit without a dedicated controller

    Compliant to global safety standards:

     

    Safety Standards: ISO13849-1 PLd, CE, TUV Rheinland, SIL2, cUL

     

    Type 3 Safety Laser Scanner complies with IEC61496-1/-3.